VSD pump control panels

VSD (inverter) pump control panels, 0.55 to 250kW

One pump on one inverter. Gentle starts for generator supplies, speed control from floats, a transducer or an ultrasonic, and plug-in sockets on the side.

Price on a written quote · typically 20 to 22 working days

Typically 20 to 22 working daysBS EN 61439BS EN 60204-1EMC Directive

One pump, one drive

0.55 to 250kW at 400V three phase. 230V single phase supply up to 2.2kW.

Generator friendly

Ramped starts at a fraction of the current a direct on line start draws.

Plugs in on site

Pump and float sockets and a generator inlet on the side.

Invertek drives

Off-the-shelf industrial inverters, quick to replace and well supported in the UK.

A G&G VSD pump control panel runs one submersible or surface pump through a variable speed drive, also called an inverter, in a ventilated steel enclosure. The drive ramps the pump up gently instead of starting it direct on line, so it draws far less current as it starts, and the generator no longer has to be sized for a direct on line start. The speed comes from a control on the door, from an ultrasonic level controller or a pressure transducer holding a set point, or from your own 4-20mA signal.

Gentle starts on a generator

A pump started direct on line draws several times its running current for a few seconds, and the generator has to be sized for that moment, not for the running load. An inverter ramps the pump up at around its full load current, so the generator is sized for the running load and the drive's harmonics, not for a starting surge. Motor starting methods compared explains the difference.

Speed matched to the level or pressure

With an ultrasonic level head or a pressure transducer, the drive speeds the pump up and down to hold a level or a pressure, rather than starting and stopping it on floats. Fewer starts, less wear and less surge in the discharge line.

Supply phase order doesn't matter

The drive makes its own three phase output, so the pump turns the same way whichever way round the generator or the site supply is connected. The forward/reverse switch on the door sets the direction, so a pump wired the other way round is corrected at the switch. The drive trips if the supply loses a phase.

Built to be plugged in on site

Most of these panels go to dewatering, overpumping and hire work, where the panel is connected by whoever is on site that day and moved on a few weeks later. So the connections go on the outside and the controls go on the door.

  • Pump and float sockets on the side of the panel, to BS EN 60309, so the pump plugs in without opening the panel.
  • A generator inlet on panels up to 55kW, sized to the drive: 32A up to 15kW, 63A up to 30kW and 125A up to 55kW.
  • Hand/off/auto, start and stop on the door, with an emergency stop as an option.
  • The drive's keypad mounted on the door, so settings and fault codes can be read with the door shut and the isolator on.
  • Thermostat-controlled filter fans to keep the drive cool.
  • Wall mounted, or on a floor stand up to 45kW.

Level and pressure control: floats, transducer or ultrasonic

The panel is set up for the way you control the pump. With floats, the pump starts and stops on level and runs at a speed set on the door. With a 4-20mA pressure transducer or an ultrasonic level controller, the drive holds a set point and varies the speed itself; the ultrasonic option comes with its head. A switch on the door changes between the panel's own speed control and an external speed signal, for a site control system or a telemetry outstation. Float switches vs ultrasonics compares the two for level control.

Your code, your labels

We build these panels as standard parts for pump manufacturers and hire companies: one drawing per size, built to it every time, under your product code and with your labels on the door. We don't hire panels out, so a hire company buying from us is buying from a supplier, not a competitor. Control panels for pump hire companies covers how that works.

Specification

Pumps1 per panel
Motor rating0.55 to 250kW
Supply3ph 400V; 1ph 230V up to 2.2kW
DriveInvertek variable speed drive
ControlFloats, 4-20mA pressure transducer, ultrasonic level controller, or an external 4-20mA speed signal
Door controlsHand/off/auto, start, stop, forward/reverse, internal or external speed select, speed control
IndicationPower on, run and fault lamps; drive keypad on the door
Emergency stopOptional, on the door
ProtectionDoor-interlocked isolator; motor overload, supply phase loss and over and under voltage protection in the drive
CoolingThermostat-controlled filter fans
ConnectionsOptional pump and float sockets to BS EN 60309, and a generator inlet up to 55kW (32, 63 or 125A)
EnclosurePowder-coated mild steel, wall mounted or on a floor stand; stainless steel on smaller sizes
Warranty12 months, return to base

Every panel ships with its wiring diagram, a test certificate and a 12-month warranty.

Options

Site

  • Generator inlet: 32A, 63A or 125A (up to 55kW)
  • Pump and float sockets on the side
  • Floor stand (up to 45kW)
  • Stainless steel enclosure (smaller sizes)

Controls

  • Emergency stop
  • Ultrasonic level controller with head
  • GSM alarm dialler
  • Timeclock
  • Hose leak sensor input

Options are priced on your quote, itemised, so you can see what each one adds.

Price and lead time

Priced to the motor kW, the supply and the options you choose, on a written quote, usually the same working day.

Typically 20 to 22 working days from order. Above 132kW the date depends on the drive, so we confirm it with the quote.

Frequently asked questions

Smaller than the same pump would need started direct on line, because an inverter start draws far less current. Inverters also put harmonics onto the supply, so give the generator supplier the pump kW and tell them the load is an inverter.

No. The drive turns the supply into its own three phase output, so the direction is set by the drive, not by the supply. The forward/reverse switch on the door sets it. Direction does still depend on how the pump is wired to the panel or its plug, so check rotation the first time a pump is connected.

Yes. The ultrasonic controller gives the drive a 4-20mA level signal and the drive speeds the pump up as the level rises and slows it as it falls, holding the level you set. The head is included with the ultrasonic option.

Yes. Floats start and stop the pump and the speed is set on the door. Floats are not included unless you ask for them.

Yes. Turn the speed select switch on the door to external and the drive follows a 4-20mA signal from your controller, telemetry outstation or site system.

Yes. We build them to your product code, with your labels on the door and your codes on the drawings and paperwork. Many of these panels go to pump manufacturers and hire companies as their own standard parts.

No. Every panel is tested in our factory before it leaves, including a full functional test, and ships with its wiring diagram and test certificate, ready for your engineer or electrician to connect.

Related panels

VSD pump panel door with run and fault lamps, hand/off/auto, speed control, emergency stop and the drive keypad

For pump hire companies

Pump hire control panels

We build control panels for hire fleets and never hire them out, so we never compete with you for a job. VSD, soft start and direct on line panels, built to one drawing per code and labelled as yours.

Each panel type is quoted once against its drawing, and repeat orders are quoted against your product code.

Twin pump booster panel closed: power, low level, run and fault lamps and a hand/off/auto switch for each pump, and the door isolator

Booster set control panels

Booster set control panels

One to six pumps held at a single pressure set point by pre-programmed inverters in the panel. Swap a drive without replacing the booster set.

Inverter panels with pressure control from £2,428 + VAT (single pump 0.75kW, 400V) and £3,946 + VAT (twin pump 0.75kW).

Door of a G&G dual pump control panel: power on, high level and mute alarm at the top, running and fault lamps for pump 1 and pump 2, two hand/off/auto switches either side of the alarm sounder, and the isolator

Twin pump control panel

Dual pump control panels

Two pumps, one panel: duty/assist with automatic changeover, a high level alarm and volt-free outputs. Built in Stoke-on-Trent, standard panels next day from stock.

From £1,245 + VAT for a dual pump DOL panel up to 18A.

Request a quote for VSD pump control panels

Tell us the pumps or points, the supply, the site and anything the panel must comply with. Attach a spec or drawing if you have one.

  • Wiring diagram, test certificate and 12-month warranty with every panel
  • Built to BS EN 61439 and BS EN 60204-1 in Stoke-on-Trent
  • We reply during working hours, usually the same working day

Request a quote

Or call 01782 280577

What happens next. A price and lead time, usually the same working day. We reply during working hours, Monday to Friday, 7am to 4.30pm.

Your details go to our sales team by email and are used only to answer this enquiry. No mailing list, nothing shared. Privacy policy.

Got a project, or just need a quick answer?

Tell us what the panel has to do and we will come back with a price and a lead time. Existing accounts: reorders and spares go through the same form.