Skip to content
G&G Controls, The Panel People

For pump hire companies

Control panels for pump hire companies, built under your brand

We build control panels for hire fleets and never hire them out, so we never compete with you for a job. VSD, soft start and direct on line panels, built to one drawing per code and labelled as yours.

Quoted per panel type · 1 to 3 weeks on repeat builds

1 to 3 weeks on repeat buildsBS EN 61439BS EN 60204-1EMC Directive

We never hire panels out

A supplier to your fleet, never a competitor for your customers.

Your brand, not ours

Your logo, labels and product codes. No G&G branding on the outside.

Plugs in on site

BS EN 60309 inlets and sockets, and generator inlets to 125A.

0.55 to 250kW

Direct on line, star-delta, soft start and variable speed.

Hire panels go out on a lorry, plug in on site, run from whatever supply is there and come back ready to go again. We build them to your design or ours: drawn once, built to the same drawing every time and labelled with your name.

Who we work with

  • Pump hire companies
  • Plant hire companies with a pump fleet
  • Dewatering and overpumping contractors
  • Cooling and HVAC hire companies
  • Pump manufacturers with a rental range

Your panel, your brand

Some panel builders hire panels out themselves. We don't, and we never will. Everything we build for a hire company goes out under that company's name: your logo and labels on the door, your product codes on the drawings and the paperwork, and no G&G branding on the outside.

Your customer sees your kit and calls your depot. The relationship stays with you, and we stay in the factory building the next batch.

What we build for hire fleets

Pump panels from 0.55 to 250kW for hire, dewatering and overpumping work, and panels for the other plant a hire fleet sends out. The VSD pump control panels page has the detail of the inverter range.

  • VSD (inverter) panels from 0.55 to 250kW, for submersible and surface pumps.
  • Direct on line, star-delta and soft start panels.
  • Single and dual pump level control panels, from floats, a transducer or an ultrasonic head.
  • Chiller changeover and other plant panels for cooling and HVAC hire.
  • Wiring looms, cable sets and control boxes for your own pump sets.

Built for hire, dewatering and overpumping sites

A hire panel is connected and disconnected many times, by different people, on different supplies. We build for that: what survives the hire cycle and pump panels on hire and dewatering sites go through each point in detail.

  • An inlet and sockets to BS EN 60309, so the supply, the pump and the floats plug in.
  • Generator inlets: 32, 63 or 125A.
  • Run and fault lamps on the door, and fault inputs that read a broken wire as a fault.
  • Phase failure and phase sequence relays on direct on line and star-delta panels. Inverters set the pump's direction themselves.
  • Steel, stainless or polyester enclosures, wall mounted or on a stand.
  • Remote alerts by text or email where nobody is on site, from a GSM dialler, or Telemetrix on smaller pumps.

One drawing per code, held on your shelf

Once the drawing for a panel type is agreed, every repeat is built to it and ordered by your product code: the same parts, the same wiring, the same test. Your depots can keep standard panels in stock and send one out the day a job comes in, and your engineers only have one layout to learn.

We did exactly this for a national cooling hire company: twenty chiller changeover panels built to one drawing set, held in their depots for urgent hires.

Bring your existing design

Many hire companies already have a panel that works, but it is built a little differently every time, sometimes by different suppliers. Send us the drawing, some photos or one of the panels. We redraw it as a standard, suggest improvements such as circuit breakers in place of fuses, and agree every change with your technical manager before we build. Send us your drawing and we will come back with a price per panel type.

Specification

StartingDirect on line, star-delta, soft start or variable speed drive
Motor rating0.55 to 250kW
Supply3ph 400V; 1ph 230V on smaller panels
ControlFloats, 4-20mA pressure transducer, ultrasonic level controller, external signal or timeclock
ConnectionsBS EN 60309 inlet and sockets; generator inlet 32, 63 or 125A
EnclosureMild steel, stainless steel or polyester; wall mounted or on a stand
BrandingYour logo, labels and product codes; no G&G branding on the outside
PaperworkSerial number, wiring diagram, test certificate and declaration of conformity with every panel
Warranty12 months, return to base

Every panel ships with its wiring diagram, a test certificate and a 12-month warranty.

Price and lead time

Each panel type is quoted once against its drawing, and repeat orders are quoted against your product code.

Repeat panels of an agreed design have typically gone out one to three weeks from order. A new design adds the time to draw and approve it, and VSD panels are typically 20 to 22 working days.

Frequently asked questions

No. We build control panels and sell them to the companies that hire them out. We never compete with you for a hire, and your customers deal with you, not us.

No. Panels we build for a hire company carry that company's labels on the door and its product codes on the paperwork, with no G&G branding on the outside.

Yes. Many hire companies already have a design that works. We redraw it as a standard, suggest improvements such as circuit breakers in place of fuses or a 24V DC control circuit, and agree every change with your technical manager before building to it.

Once the drawing is approved, repeat panels of a standard design have typically gone out one to three weeks from order. VSD panels are typically 20 to 22 working days.

No. Every panel is tested in our factory, including a full functional test, and ships with its wiring diagram and test certificate, ready for your engineers to connect. We don't do site work, so we never turn up on your customer's site either.

Yes. Every panel we build is designed and tested to BS EN 61439-2 and ships with a declaration of conformity and a test certificate.

Yes. We fit generator inlets of 32, 63 or 125A, and a soft starter or inverter reduces the starting current the generator has to cope with.

Further reading

All articles →
Control panels for a hire fleet: what survives the hire cycle

Control panels for a hire fleet: what survives the hire cycle

What hire companies should ask a panel builder for: one drawing per panel, plug-in connections, outdoor enclosures, fail-safe faults and the paperwork for between hires.

5 November 2026 · 6 min read

Pump control panels on hire and dewatering sites: generators, phase rotation and unattended running

Pump control panels on hire and dewatering sites: generators, phase rotation and unattended running

What a hire or dewatering pump panel needs: phase rotation and phase failure protection, generator inlets, safe restarts after a power cut, level control and remote alerts.

19 November 2026 · 6 min read

Motor starting methods: DOL, star/delta, soft start and inverter

Motor starting methods: DOL, star/delta, soft start and inverter

When designing control panels, selecting the right motor starting method is a key decision that can affect cost, reliability, and long-term performance.

27 June 2025 · 4 min read

Chiller changeover panels explained: duty rotation, assist and trip changeover

Chiller changeover panels explained: duty rotation, assist and trip changeover

How a chiller changeover panel runs two or three chillers on one load: duty and assist, weekly duty rotation, fail-safe trip changeover, 24V DC control and what to specify.

12 November 2026 · 6 min read

Standardising a control panel platform: how OEMs take cost and lead time out

Standardising a control panel platform: how OEMs take cost and lead time out

Equipment makers often order too many panel variants. How to design one platform with option blocks, what it saves, and how to move a range across to it.

21 August 2026 · 4 min read

What a control panel test certificate should include, and what to ask for

What a control panel test certificate should include, and what to ask for

What a proper control panel test certificate records, what the tests mean, and the questions to ask a panel builder before you order.

3 July 2026 · 4 min read

Related panels

37kW VSD pump panel door with run and fault lamps, hand/off/auto, speed control, emergency stop and the drive keypad

VSD pump control panels

VSD pump control panels

One pump on one inverter. Gentle starts for generator supplies, speed control from floats, a transducer or an ultrasonic, and plug-in sockets on the side.

Priced to the motor kW, the supply and the options you choose, on a written quote, usually the same working day.

Door of a G&G dual pump control panel: power on, high level and mute alarm at the top, running and fault lamps for pump 1 and pump 2, two hand/off/auto switches either side of the alarm sounder, and the isolator

Twin pump control panel

Dual pump control panels

Two pumps, one panel: duty/assist with automatic changeover, a high level alarm and volt-free outputs. Built in Stoke-on-Trent, standard panels next day from stock.

From £1,245 + VAT for a dual pump DOL panel up to 18A.

G&G engineers building control panels on the factory floor in Stoke-on-Trent

Equipment manufacturers

OEM control panels

Fixed BOMs, one standard platform for your range, and reliable UK production at 5 to 200 panels a month.

Fixed unit price per platform and option block, agreed at design stage and held across the programme.

Request a quote for Pump hire control panels

Tell us the pumps or points, the supply, the site and anything the panel must comply with. Attach a spec or drawing if you have one.

  • Wiring diagram, test certificate and 12-month warranty with every panel
  • Built to BS EN 61439 and BS EN 60204-1 in Stoke-on-Trent
  • We reply during working hours, usually the same working day

Request a quote

Or call 01782 280577

What happens next. A price per panel type and a lead time, usually within two working days. We reply during working hours, Monday to Friday, 7am to 4.30pm.

Your details go to our sales team by email and are used only to answer this enquiry. No mailing list, nothing shared. Privacy policy.

Got a project, or just need a quick answer?

Tell us what the panel has to do and we will come back with a price and a lead time. Existing accounts: reorders and spares go through the same form.