For pump hire companies
Control panels for pump hire companies, built under your brand
We build control panels for hire fleets and never hire them out, so we never compete with you for a job. VSD, soft start and direct on line panels, built to one drawing per code and labelled as yours.
Quoted per panel type · 1 to 3 weeks on repeat builds
We never hire panels out
A supplier to your fleet, never a competitor for your customers.
Your brand, not ours
Your logo, labels and product codes. No G&G branding on the outside.
Plugs in on site
BS EN 60309 inlets and sockets, and generator inlets to 125A.
0.55 to 250kW
Direct on line, star-delta, soft start and variable speed.
Hire panels go out on a lorry, plug in on site, run from whatever supply is there and come back ready to go again. We build them to your design or ours: drawn once, built to the same drawing every time and labelled with your name.
Who we work with
- Pump hire companies
- Plant hire companies with a pump fleet
- Dewatering and overpumping contractors
- Cooling and HVAC hire companies
- Pump manufacturers with a rental range
Your panel, your brand
Some panel builders hire panels out themselves. We don't, and we never will. Everything we build for a hire company goes out under that company's name: your logo and labels on the door, your product codes on the drawings and the paperwork, and no G&G branding on the outside.
Your customer sees your kit and calls your depot. The relationship stays with you, and we stay in the factory building the next batch.
What we build for hire fleets
Pump panels from 0.55 to 250kW for hire, dewatering and overpumping work, and panels for the other plant a hire fleet sends out. The VSD pump control panels page has the detail of the inverter range.
- VSD (inverter) panels from 0.55 to 250kW, for submersible and surface pumps.
- Direct on line, star-delta and soft start panels.
- Single and dual pump level control panels, from floats, a transducer or an ultrasonic head.
- Chiller changeover and other plant panels for cooling and HVAC hire.
- Wiring looms, cable sets and control boxes for your own pump sets.
Built for hire, dewatering and overpumping sites
A hire panel is connected and disconnected many times, by different people, on different supplies. We build for that: what survives the hire cycle and pump panels on hire and dewatering sites go through each point in detail.
- An inlet and sockets to BS EN 60309, so the supply, the pump and the floats plug in.
- Generator inlets: 32, 63 or 125A.
- Run and fault lamps on the door, and fault inputs that read a broken wire as a fault.
- Phase failure and phase sequence relays on direct on line and star-delta panels. Inverters set the pump's direction themselves.
- Steel, stainless or polyester enclosures, wall mounted or on a stand.
- Remote alerts by text or email where nobody is on site, from a GSM dialler, or Telemetrix on smaller pumps.
One drawing per code, held on your shelf
Once the drawing for a panel type is agreed, every repeat is built to it and ordered by your product code: the same parts, the same wiring, the same test. Your depots can keep standard panels in stock and send one out the day a job comes in, and your engineers only have one layout to learn.
We did exactly this for a national cooling hire company: twenty chiller changeover panels built to one drawing set, held in their depots for urgent hires.
Bring your existing design
Many hire companies already have a panel that works, but it is built a little differently every time, sometimes by different suppliers. Send us the drawing, some photos or one of the panels. We redraw it as a standard, suggest improvements such as circuit breakers in place of fuses, and agree every change with your technical manager before we build. Send us your drawing and we will come back with a price per panel type.
Specification
| Starting | Direct on line, star-delta, soft start or variable speed drive |
|---|---|
| Motor rating | 0.55 to 250kW |
| Supply | 3ph 400V; 1ph 230V on smaller panels |
| Control | Floats, 4-20mA pressure transducer, ultrasonic level controller, external signal or timeclock |
| Connections | BS EN 60309 inlet and sockets; generator inlet 32, 63 or 125A |
| Enclosure | Mild steel, stainless steel or polyester; wall mounted or on a stand |
| Branding | Your logo, labels and product codes; no G&G branding on the outside |
| Paperwork | Serial number, wiring diagram, test certificate and declaration of conformity with every panel |
| Warranty | 12 months, return to base |
Every panel ships with its wiring diagram, a test certificate and a 12-month warranty.
Price and lead time
Each panel type is quoted once against its drawing, and repeat orders are quoted against your product code.
Repeat panels of an agreed design have typically gone out one to three weeks from order. A new design adds the time to draw and approve it, and VSD panels are typically 20 to 22 working days.
Frequently asked questions
Further reading
All articles →
Control panels for a hire fleet: what survives the hire cycle
What hire companies should ask a panel builder for: one drawing per panel, plug-in connections, outdoor enclosures, fail-safe faults and the paperwork for between hires.
5 November 2026 · 6 min read

Pump control panels on hire and dewatering sites: generators, phase rotation and unattended running
What a hire or dewatering pump panel needs: phase rotation and phase failure protection, generator inlets, safe restarts after a power cut, level control and remote alerts.
19 November 2026 · 6 min read

Motor starting methods: DOL, star/delta, soft start and inverter
When designing control panels, selecting the right motor starting method is a key decision that can affect cost, reliability, and long-term performance.
27 June 2025 · 4 min read

Chiller changeover panels explained: duty rotation, assist and trip changeover
How a chiller changeover panel runs two or three chillers on one load: duty and assist, weekly duty rotation, fail-safe trip changeover, 24V DC control and what to specify.
12 November 2026 · 6 min read

Standardising a control panel platform: how OEMs take cost and lead time out
Equipment makers often order too many panel variants. How to design one platform with option blocks, what it saves, and how to move a range across to it.
21 August 2026 · 4 min read

What a control panel test certificate should include, and what to ask for
What a proper control panel test certificate records, what the tests mean, and the questions to ask a panel builder before you order.
3 July 2026 · 4 min read
Related panels

VSD pump control panels
VSD pump control panels
One pump on one inverter. Gentle starts for generator supplies, speed control from floats, a transducer or an ultrasonic, and plug-in sockets on the side.
Priced to the motor kW, the supply and the options you choose, on a written quote, usually the same working day.

Twin pump control panel
Dual pump control panels
Two pumps, one panel: duty/assist with automatic changeover, a high level alarm and volt-free outputs. Built in Stoke-on-Trent, standard panels next day from stock.
From £1,245 + VAT for a dual pump DOL panel up to 18A.

Equipment manufacturers
OEM control panels
Fixed BOMs, one standard platform for your range, and reliable UK production at 5 to 200 panels a month.
Fixed unit price per platform and option block, agreed at design stage and held across the programme.
Request a quote for Pump hire control panels
Tell us the pumps or points, the supply, the site and anything the panel must comply with. Attach a spec or drawing if you have one.
- Wiring diagram, test certificate and 12-month warranty with every panel
- Built to BS EN 61439 and BS EN 60204-1 in Stoke-on-Trent
- We reply during working hours, usually the same working day
Got a project, or just need a quick answer?